QUARTERLY JOURNAL OF THE JAPAN WELDING SOCIETY
Online ISSN : 2434-8252
Print ISSN : 0288-4771
Evaluation of Cold Crack Susceptibility in Weld Metal of High Strength Steels Using the LB-TRC Test
Cold Cracking Susceptibility in Weld Metal of HY-Steel (Part 3)
Fukuhisa MatsudaHiroji NakagawaKenji Shinozaki
Author information
JOURNAL FREE ACCESS

1987 Volume 5 Issue 2 Pages 239-243

Details
Abstract

In this study, the effects of hardness and diffusible hydrogen content on the lower critical stresses o f weld metals (LCS) of high strength steels in the strength range 490 to 1950 MPa were evaluated utilizing the LB-TRC test which was newly developed in order to understand the cold cracking characteristics of weld metal.
Test beads were laid utilizing SMA welding and GTA welding in which argon and argon-(0.35, 1.0, 2.0, 3.2 Vol.%) hydrogen mixed gases were used as shielding gases. The diffusible hydrogen content range was 0.1 to 9 ml/100 g. Moreover, yield strength of root-pass deposited metal ((σr)y) and fracture stress of LB-TRC tested specimen which had evolved diffusible hydrogen for 10 days at room temperature (σ*F) were measured in order to evaluate the cold cracking susceptibility. σ*F was regarded as the hydrogen-free LCS, so the cold cracking susceptibility of weld metal was evaluated using two parameters such as σcr/(σr)y and (σ*Fcr)/σ*F.
Consequently, the LCS of weld metals of high strength steels decreased rapidly with an increase in the diffusible hydrogen content in the range 0 to 3 ml/100 g. Moreover, cold cracking susceptibility in weld metal increased with an increase in strength level and/or hardness and then especially, weld metals of HY130 and HY150 were most susceptible to cold cracking rather than that of HY180.

Content from these authors
© by JAPAN WELDING SOCIETY
Previous article Next article
feedback