QUARTERLY JOURNAL OF THE JAPAN WELDING SOCIETY
Online ISSN : 2434-8252
Print ISSN : 0288-4771
An Experimental Study on Weld Crack by the Pulating Load
Izumi ImotoYasumasa NakanishiKohsuke Horikawa
Author information
JOURNAL FREE ACCESS

1989 Volume 7 Issue 3 Pages 319-325

Details
Abstract

In recent years, bridge and highways have been, occasionally damaged because of increased in the volume of traffic and/or the gross weights of vehicles, and therefore it has been often become neccesary to perform welding for repair and reinforcement work, if possible in daytime without traffic control.
In this study, the welding crack by the pulsating load in bridge under service condition was studied under the welding crack test by the pulsating load, the trans-varestraint test for weld metal and the high temperature tensile test for weld metal.
The following main results were obtained;
1) The welding crack by pulsating load is hot crakcs in solidification-liquid mixed and solidification, and often occur due to external strain caused by pulsating load.
2) The welding crack in solidification occurs more than about 1100°C.
3) The critical loading strain of welding crack are follows; D4316, D5816 : About 1% in solidification-liquid mixed
D4316:About 2% in solidification
D5816:About 3% in solidification

Content from these authors
© by JAPAN WELDING SOCIETY
Previous article Next article
feedback
Top