QUARTERLY JOURNAL OF THE JAPAN WELDING SOCIETY
Online ISSN : 2434-8252
Print ISSN : 0288-4771
Brazing of Titanium with Ti-Cu-Cr Filler Alloy
Ken SasabeKazuo Hirano
Author information
JOURNAL FREE ACCESS

1990 Volume 8 Issue 3 Pages 354-359

Details
Abstract

Mechanical properties of work hardened pure titanium joint brazed with Ti-Cu-Cr-Al filler metal were investigated.
Test specimens were brazed with filler metal containing 29%Ti, 62.5%Cu, 6.5%Cr and 2%Al in a vacuum. Brazing temperature were 850°C, 900°C, 1, 000°C and 1, 100°C for 10sec. Tensile strength of butt joints were comparable to that of joints brazed with conventional Ti-Ni-Cu filler metal, and hardness at the joint was lower. The reaction of filler metal with base metal was modertely and damage of base metals were less. The addition of pressure to joint during brazing gave significant effect on joint strength.

Content from these authors
© by JAPAN WELDING SOCIETY
Previous article Next article
feedback