Advances in River Engineering
Online ISSN : 2436-6714
NON-CONTACT RIVER DISCHARGE MEASUREMENT IN UPSTREAM RIVER USING RADIO CURRENT METER
Minoru ONDARyuichi HIRAKAWATomohiro OHNOJin KASHIWADAYusuke YAMASAKITakuya INOUEAkihiro ABE
Author information
JOURNAL FREE ACCESS

2015 Volume 21 Pages 95-98

Details
Abstract

In the present study, to build a river-discharge measurement system without floats in upstream, we have attempted to apply a radio current meter in a flood-flow measurement in Tone River. The observed results indicate that the water-surface velocity using a radio current meter has an influence of the wind. However, the measurement accuracy of the velocity using a radio current meter considered by the effect of wind are good agreements with those of ADCP. It is noteworthy that the coefficient of float show increasing and decreasing trend as water depth and the averaged coefficient of float are as same as the standard value. Therefore we can apply the standard value of the coefficient of float to the velocity using a radio current meter.

Content from these authors
© 2015 Japan Society of Civil Engineers
Previous article Next article
feedback