Quarterly Report of RTRI
Online ISSN : 1880-1765
Print ISSN : 0033-9008
ISSN-L : 0033-9008
PAPERS
Nomogram for the Installation Specification of Drain Pipes for Embankments
Satoshi WATANABENaoyuki OTA
Author information
RESEARCH REPORT / TECHNICAL REPORT FREE ACCESS

2015 Volume 56 Issue 4 Pages 272-277

Details
Abstract
Groundwater levels in embankments often rise due to heavy rainfall, which can occasionally cause embankments to collapse. In order to decrease the ground water level, it is important to take countermeasures to drain the water from areas in embankments which could weaken in heavy rain. The drain pipe method for embankments has been adopted widely by Japanese railways as a water draining method. However, installation specifications for drain pipes have not yet been established, and the finer details of construction work currently depend on experience. This study therefore set out to evaluate the effect of drain pipes quantitatively, with a view to proposing a set of installation specifications for drain pipes in embankments, based on the evaluation and considering the height of the embankment, external permeance, inter alia.
Content from these authors
© 2015 by Railway Technical Research Institute
Previous article Next article
feedback