Quarterly Report of RTRI
Online ISSN : 1880-1765
Print ISSN : 0033-9008
ISSN-L : 0033-9008
PAPERS
Method for Estimating Molten Volume of Current Collecting Materials at Contact Loss Point using ϕ-θ Theory
Chikara YAMASHITAKoki NEMOTOTakuya OHARA
Author information
RESEARCH REPORT / TECHNICAL REPORT FREE ACCESS FULL-TEXT HTML

2025 Volume 66 Issue 2 Pages 72-77

Details
Abstract

In order to control electric wear of current collecting materials such as contact wires and contact strips in electric railways, it is necessary to understand the relationship between current and the molten volume at a contact loss point. In this paper, we propose a method for estimating the molten volume of the contact wire whose film resistance is taken into account, on the basis of the ϕ-θ theory. To verify the proposed method, we carried out wear tests under varying current conditions to measure the molten depth, molten radius, and molten volume. The wear test results showed that the experimental values of the molten volume of the contact wire are spread in the range where normalized potential at the contact boundary at which α was estimated to be 0.90 to 0.94.

Content from these authors
© 2025 by Railway Technical Research Institute
Previous article Next article
feedback
Top