Abstract
In this research, under various conditions, we evaluate the water cut-off performance of H-jointed steel pipe sheet piles (SPSPs) with the H-H joints attaching water-swelling materials which are components of SPSPs for water cut-off in a coastal waste landfill site. Specifically, we research the water cut-off performance when these H-H joints have foreign particles, when they are in a wet-dry cyclic condition, and when the water-swelling material has deteriorated. As a result of this research, it has been found that in any of the above cases, H-jointed SPSPs with H-H joints attaching water-swelling materials are capable of providing water cut-off performance, and meet seepage control work standards as long as they are under less than certain pressure levels to be considered in coastal waste landfill sites. Also, it has been proved that the above conditions do not affect the water cut-off performance of H-jointed SPSPs with H-H joints attaching water-swelling materials.