Surgery for Cerebral Stroke
Online ISSN : 1880-4683
Print ISSN : 0914-5508
ISSN-L : 0914-5508
Topics: Safety Procedure of CEA
The Usefulness of Guide Wire to Insert the Shunt Tube During Carotid Endarterectomy
Kojiro WADAHiroshi NAWASHIROHidenori OHKAWAHirohiko ARIMOTODaisuke MAEDAToshiki SHIROTANI
Author information
JOURNAL FREE ACCESS

2011 Volume 39 Issue 4 Pages 253-256

Details
Abstract
Carotid endarterectomy (CEA) is a standard treatment for the internal carotid artery stenosis, but the routine use of internal shunt tube during CEA is controversial. The carotid bifurcation of Japanese is reported to be higher than that of Europeans. Therefore, it is somewhat difficult to insert the internal shunt into the internal carotid artery. The purpose of this study is to clarify the usefulness and feasibility of using a guide-wire to insert an internal shunt tube into internal carotid artery.
Between 2007 and 2009, 24 CEAs for 24 consecutive patients with internal carotid artery stenosis were performed in our institute. We routinely used an internal shunt tube. Twenty-two CEAs were performed using the internal shunt tube. Internal shunt tubes were not used for 2 near-occlusion CEA cases. For 11 of the CEAs, we used a 3.5-inch guide-wire to insert the internal shunt tube. We compared the time required to insert the tube in the guide-wire group and the without guide-wire group. The average time required for the guide-wire group was 6.8 minutes, and the without guide-wire group required 9.5 minutes. The guide-wire group required significantly (P<0.05) less time than the without guide-wire group.
We consider using a guide-wire during the insertion of the internal shunt tube for CEA to be useful.