The diffusion coefficients of chromium in 11 Ni/18 Cr stainless steel (AISI 329) were determined over a temperature range of 1050-1150°C as a sudy of the 1st stage on the diffusion coating of electroplated chromium.
The results obtained were summarized as follows (in the unit of cm2/sec.):
1050°C D=7.91×10-10(0.39 Cr)-2.55×10-11(0.80 Cr)
1100°C D=6.32×10-10(0.45 Cr)-2.11×10-11(0.90 Cr)
1150°C D=2.73×10-9(0.35 Cr)-4.50×10-11(0.91 Cr)