Abstract
In this paper, we have concluded that three sine pressure tests using a simple test devises is valid as a test method of trap performance. Three sine pressure tests created from actual pressures which were applied Low Pass Filter Processing of 3 Hz were carried out using a Simple Test Devices. The results were compared with those of the discharge experiments, and no significant differences were detected. In addition, the basic performances of the standard traps were confirmed.