Techinical Papers of Annual Meeting the Society of Heating,Air-conditioning and Sanitary Engineers of Japan
Online ISSN : 2424-2179
Print ISSN : 1880-3806
ISSN-L : 1880-3806
2010.2
Session ID : A-24
Conference information
A-24 Study of the Drainage Performance Improvement Technique of Drainage Stack System by means of Air Admittance Valves : Part3. An application of the Single Air Admittance Valves to the horizontal fixture drain branch
Shin KOUNOMasayuki OTSUKAZhe ZhangTsubasa UENO
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
This report propose a prediction method for drainage performance, which use the evaluation indices acquired by measuring a pipe pressure variation and an air flow rate when air-admittance valves are installed in a locations along the horizontal fixture drain branch of a drainage stack system. And examines how the change of the negative pressure value and the positive pressure value of pipe pressure affects the drainage performance.
Content from these authors
© 2010 The Society of Heating,Air-Conditioning&Sanitary Engineers of Japan
Previous article Next article
feedback
Top