B-52 Performance Evaluation of Ground Source Heat Pump System Installed in a Detached Wooden House in Sendai
Yoshimi ISHIKAWA
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
Thermal performance of the ground source heat pump (GSHP) system installed in a detached wooden house in Sendai was measured for more than one year. As the results of the investigation, the system coefficient of performance was about 2.6 in January and from 0.5 to 2.9 in August. In addition, it was found that, in the winter, the principle of the energy conservation among the heating output of GSHP, the pumped heat from the ground and the electric power consumption was realized, and, GSHP was superior in the environmental property and the cost performance to the kerosene heater.
Content from these authors
© 2010 The Society of Heating,Air-Conditioning&Sanitary Engineers of Japan