The Japanese Journal of Conservative Dentistry
Online ISSN : 2188-0808
Print ISSN : 0387-2343
ISSN-L : 0387-2343
Original Articles
Effect of Cavity Configuration on Bonding of Self-etch Adhesive Systems to Cavity Floor Dentin : Examination of Bonding Reliability
Mitsuru HASEGAWAYoichiro NARA
Author information
JOURNAL FREE ACCESS

2009 Volume 52 Issue 1 Pages 68-80

Details
Abstract

Recently resin composite restoration has been applied in various clinical cases with the development and improvement of dental devices and materials. However, the fatal occurrence of polymerization shrinkage within a resin composite restorative is an important factor that affects the clinical prognosis of the restoration. The purpose of this study was to examine the effect of cavity configuration on the bonding reliability of two self-etch adhesive systems, i.e., an one-bottle all-in-one system; Clearfil Tri-S Bond (TS, Kuraray Medical), and a two-bottle self-etching primer system; Clearfil Mega Bond (MB, Kuraray Medical), to cavity floor dentin. The occlusal enamel of extracted human molars was ground horizontally to expose a flat dentin surface. Five standardized cavities, i.e., Class I (4.0mm long, 4.0mm wide, 2.0mm deep, C-value=3.0), MO (1.7), MOD (1.0), MODB (0.7), and Flat (0.3), were prepared on the flat dentin surface (n=10, each cavity). Every cavity was pretreated with either TS or MB, in accordance with the manufacturer's instructions, and the same volume of universal resin composite restorative, Clearfil AP-X (Kuraray Medical), was placed into each cavity and then light cured. After storage in a moisture box at 37℃ for 24 hours, restored tooth specimens were sectioned vertically into four quadrate stick form specimens (1.0×1.0mm). The micro-tensile bond strengths (μ-TBS) of the stick specimens were then measured. The data of the μ-TBS obtained from the five types of cavities restored with two different adhesive systems were examined using Weibull analysis (n=20). Regardless of the system, the Weibull modulus of Class I (3.0) indicated the maximum value and that of Flat (0.3) indicated the minimum value. The Weibull modulus of the standardized cavity increased with decreasing C-value, and the value of MB was statistically greater than that of TS. From the results, the bonding reliability of the cavity increased as the C-value decreased. The reliability of MB was superior to TS. However, that of MB was superior to TS only for Class I (3.0); there were no differences in the reliability between the two systems in the other four cavity configurations (1.7-0.3).

Content from these authors
© 2009 The Japanese Journal of Conservative Dentistry
Previous article Next article
feedback
Top