Shikaigaku
Online ISSN : 2189-647X
Print ISSN : 0030-6150
ISSN-L : 0030-6150
Evaluation of a non-invasive, continuous measurement of periodontal blood flow in cats
Shigeru OGINO
Author information
JOURNAL FREE ACCESS

1992 Volume 55 Issue 6 Pages 594-595

Details
Abstract

A non-invasive, continuous measurement of blood flow through the periodontal membrane in cats was attempted, using laser Doppler velocimetry (LDV). I examined whether the LDV readings reliably reflected the blood flow in the test region by simultaneous measurement of the periodontal membrane blood flow by the hydrogen clearance method. It was found that LDV allowed the recording of oscillatory changes in blood flow synchronous with cardiac rhythm. Blood flow was reduced by local adrenaline treatment. Percent changes in periodontal membrane blood flow, measured by LDV, correlated well with those measured by the hydrogen clearance method, indicating that the LDV readings reliably reflected actual blood flow.

Content from these authors
© 1992 Osaka Odontological Society
Previous article Next article
feedback
Top