Journal of Structural Engineering, A
Online ISSN : 1881-820X
Fatigue resistance test of precast PC-slab jointed with high-strength fiber reinforced mortar and screw-type rebar
Katsuya IkenoYoshihiro KurakawaKenichi MizunoRuben VargasTakuya MaeshimaIchiro Iwaki
Author information
JOURNAL FREE ACCESS

2024 Volume 70A Pages 708-717

Details
Abstract

The objective of this study is to investigate the fatigue resistance of a slab system consisting of precast PC slabs and a novel joint system consisting of high-strength fiber reinforced mortar and screw-type rebar. The fatigue resistance is assessed through a wheel load test, initially designed to comply with the NEXCO 442 test method to ensure a 100-year service life; subsequently, the test has been extended to further verify fatigue resistance at higher repetitions, higher loads and in wet conditions. The results demonstrate that the slab system's fatigue life largely surpasses 100 years. Furthermore, comprehensive post-test investigation confirmed that no significant or localized damage occurred to either the joint system or the slab during the test.

Content from these authors
© 2024 by Japan Society of Civil Engineers
Previous article Next article