2014 Volume 100 Issue 12 Pages 1508-1513
Cooling equipment of the pipe laminar type is utilized on run-out tables in hot strip mills. It is known that the stability of the water flow injected from the cooling equipment nozzles affects cooling performance. In this study, new criteria and an experimental method for quantifying water flow stability are proposed. The experimental apparatus consists of the water injection equipment, an electric circuit and a logger. The time variation of voltage represents the electric resistance of the injected water and is measured under various conditions of flow rate and nozzle diameter. We propose a new laminar stability index, σV/VAVE, in which σV and VAVE mean the standard deviation and the average value of voltage, respectively. The proposed index qualitatively shows good agreement with the appearance of the laminar flow in the experiment. Based on the experiment, an equation of continuous laminar length is suggested.