Tetsu-to-Hagane
Online ISSN : 1883-2954
Print ISSN : 0021-1575
ISSN-L : 0021-1575
Corrosion and Plugging Behavior of Carbon Steel Pipes with Special Reference to Microbial Corrosion
Toshinori OZAKIHiroshi ASANO
Author information
JOURNAL OPEN ACCESS

1985 Volume 71 Issue 8 Pages 1032-1039

Details
Abstract
Various feed water pipes which were used for supplying cooling water to turbines in hydroelectric power stations for three to twenty years showed severe plugging problems because of tuberculation. Beneath tubercles, locally corroded large pits were observed.
Results of water and corrosion product analysis suggest that bacteria might be associated with the tuberculation. Qualitical analysis of the tuberculation suggests the preventive ways of plugging or corrosion penetration.
Content from these authors
© The Iron and Steel Institute of Japan

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/
Previous article Next article
feedback
Top