Tetsu-to-Hagane
Online ISSN : 1883-2954
Print ISSN : 0021-1575
ISSN-L : 0021-1575
Analysis of Raw Materials for Iron and Steel with X-ray Computed Tomographic Scanner
Isamu TAGUCHIKohki TANAKA
Author information
JOURNAL OPEN ACCESS

1986 Volume 72 Issue 10 Pages 1629-1636

Details
Abstract
X-ray computed tomographic scanner (CTS) recently reported for iron and steel analysis by one of the present authors, has been applied in this paper to raw materials for iron and steel, especially iron ore sinter, in a series of study on application of computed tomographic scanner to non-medical purposes.
High-voltage X-ray tube (max 420 kV, 3 mA) with an iron filter of 7 mm thickness was studied and used for high quality of tomographic images. Raw materials showed higher X-ray transmission than iron and steel and the total measuring time was shortened to 6 min. (data acquisition: 5 min, data processing: 1 min, total measuring time of iron and steel: 11 min)
The images of iron ore sinter, taken by CTS were found to be well agreed with those observed by an optical microscope after cutting and polishing the sinter.
Using the mini-computer and the displayer of CMA (Computer aidded Micro Analyzer), CTS data of the sinter were furthermore processed in order to obtain the quantitative information of pores and residual iron ores.
It is concluded that CTS is a new apparatus suitable to analyze raw materiales for iron and steel.
Content from these authors
© The Iron and Steel Institute of Japan

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/
Previous article Next article
feedback
Top