Tetsu-to-Hagane
Online ISSN : 1883-2954
Print ISSN : 0021-1575
ISSN-L : 0021-1575
Fatigue Fracture of Ti-5Al-2. 5Sn ELI Alloy at Liquid Helium Temperature
Kotobu NAGAIToshio OGATATetsumi YURIKeisuke ISHIKAWATakashi NISHIMURATakao MIZOGUCHIYoshimasa ITO
Author information
JOURNAL FREE ACCESS

1986 Volume 72 Issue 6 Pages 641-648

Details
Abstract

S-N curves of Ti-5Al-2.5Sn ELI alloy were determined at liquid helium temperature (4 K) for both the base and the welded materials.
The base material had longer fatigue life at 4 K than at 77 K. Welding deteriorated the fatigue property at 4 K. Internal crack initiation was seen at the lower cyclic stress for both the base and the welded material. For the base material, the internal initiation occurred only at 4 K and there were no defects near the initiation sites. On the other hand, fatigue cracks generally initiated at blow holes for the weldment. Internal crack initiation is considered one of the causes to scatter or shorten the fatigue life.
High frequency brought about large temperature increase inside the specimen and it made the testing temperature uncertain in fatigue tests at cryogenic temperature.

Content from these authors
© The Iron and Steel Institute of Japan
Previous article Next article
feedback
Top