Measurement of Macro Strain in the Course of Reduction of the Skeletal Hematite in Sinter
Minoru ASADAMasashi SHIMAYasuo OMORI
Author information
JOURNAL OPEN ACCESS

1987 Volume 73 Issue 15 Pages 1901-1908

Details
Abstract
In order to make clear the mechanism of the reduction degradation of iron ore sinter, the macro strain in the skeletal hematite during reduction was measured.
The results obtained are as follows :
(1) The strain is scarcely remained in the skeletal hematite in the iron ore sinter.
(2) The difference of the mechanism of the reduction degradation of iron ore sinter is made clear in some kinds of reducing gas such as carbon monoxide, hydrogen and the gas mixture of carbon monoxide and carbon dioxide (35%).
(3) In the case of the reduction by CO and CO + CO2 (35%), the crack is formed immediately after reaching the maximum strain, 0.50.6, in the crystal, but the strain curve is not obtained during reduction by H2 gas.
Content from these authors
© The Iron and Steel Institute of Japan

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/