Tetsu-to-Hagane
Online ISSN : 1883-2954
Print ISSN : 0021-1575
ISSN-L : 0021-1575
Method of Sinter Pot Test of Evaluation for Dioxins Formation on Iron Ore Sintering
Takazo KAWAGUCHIMasaru MATSUMURA
Author information
JOURNAL OPEN ACCESS

2002 Volume 88 Issue 1 Pages 16-22

Details
Abstract
The new law concerning dioxins is promulgated in Japan, the iron ore sintering plants enforcing the suppression of dioxins emission. The present paper reports a study on the method and conditions of sinter pot test to evaluate dioxins and Cl content in exhaust gas. Main results obtained are as bellow. Cl is partly trapped on wind box and outlet tube of sinter pot apparatus, but dioxin is not trapped. Repeatability of measured dioxin concentration is as same as ones of NOx and SOx concentration in sinter pot test under the condition of constant flow rate of exhaust gas. Dioxins concentration in sinter pot were in good agreement with one in actual plant. These results conclude that sinter pot test is effective to evaluate dioxins.
Content from these authors
© The Iron and Steel Institute of Japan

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/
Previous article Next article
feedback
Top