Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers
Online ISSN : 2185-789X
Print ISSN : 1344-4905
ISSN-L : 1344-4905
Papers
Freeze Concentration of Liquid Droplet Fallen on a Plate in Cold Room
―Experiments for Increasing of Concentrated Liquid―
Tetsuo HIRATAHiroyuki KUMANOShin-ichi TSUDADaisuke IKEJIRI
Author information
JOURNAL FREE ACCESS

2011 Volume 28 Issue 4 Pages 331-339

Details
Abstract
Experiments on freeze concentration of liquid droplet fallen on a horizontal plate located in a cold room have been performed. Ethylene glycol aqueous solutions of 5wt% and 10wt% have been frozen to examine freeze concentration characteristics. In order to increase concentrated liquid, two devices have been tried, which are to locate a vertical acrylic resin rod at the drop area and to make large size of liquid droplet. It is shown that these devices are available to increase the concentrated liquid. It is also shown that the device of making large size of liquid droplet is more desirable than that of acrylic resin rod, because solute contaminant in ice for large size of liquid droplet is less than that of acrylic resin rod. It is found that a device to make ice having a shape of large diameter and circular cross section is preferable to increase the concentrated liquid under a condition of smaller value of distribution coefficient.
Content from these authors
© 2011 Japan Society of Refrigerating and Air Conditioning Engineers