Performance Tests of Shell and Plate Type Evaporator for OTEC
Tsutomu NAKAOKAHaruo UEHARA
Author information
JOURNAL FREE ACCESS

1986 Volume 3 Issue 2 Pages 85-96

Details
Abstract
Performance tests on a shell and plate type evaporator (total surface area = 21.95m2, length = 1450mm, width = 235mm, plate number = 100) for ocean thermal energy conversion (OTEC) plants. Freon 22 (R22) and ammonia (NH3) are used as working fluid. The empirical correlations are proporsed in order to predict the boiling heat transfer when using R22 and NH3 and water side heat transfer coefficients for a shell and plate type evaporator. The water side pressure drop is about 3 m at the warm water velocity of 0.7 m/s. The water side friction factor is obtained.
Content from these authors
© 1986 Japan Society of Refrigerating and Air Conditioning Engineers