Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers
Online ISSN : 2185-789X
Print ISSN : 1344-4905
ISSN-L : 1344-4905
Performance of a Small-sized Refrigeration Comperssor Using HFC-134a
Hirokatsu KOHSOKABEKazuhiro ENDOHYoshifumi KUNUGIHiroshi IWATAHiroaki HATAMitsuru FUJIWARA
Author information
JOURNAL FREE ACCESS

1992 Volume 9 Issue 3 Pages 291-294

Details
Abstract
When CFC-12 is replaced by HFC-134a in small-sized refrigeration compressors for domestic refrigerators, the coefficient of performance (COP) of rotary compressors decreases. On the other hand,the COP of reciprocating compressors is almost the same as that of CFC-12. The main causes of rotary compressor performance decrease are higher viscosity of HFC-134a/oil mixture,and greater re-expansion loss of gas in clearance volume. The performance is improved by optimizing the oil viscosity through directly measuring viscosity of HFC-134a/oil mixture inside the compressor chamber with a viscosity sensor. Difference of oil type has small influence on the COP.
Content from these authors
© 1992 Japan Society of Refrigerating and Air Conditioning Engineers