Abstract
A novel molecular dispersed polymer alloy composed of polyethylene (PE) and poly(vinyl acetate) (PVAc) with a biocompatible surface was developed for fabricating medical devices. The acetyl group on the surface of this polymer alloy was converted to the hydroxyl group following the phosphorylcholine (PC) group having an excellent biocompatibility. After surface-initiator was immobilized by making the hydroxyl group on the surface reacting with 2-bromoisobutyryl bromide, 2-methacryloyloxyethyl phosphorylcholine (MPC) was polymerized from the surface by the surface-initiated atom transfer radical polymerization method. The chain length of the poly(MPC) grafts was varied via the ratio of MPC to sacrificial initiator. The surfaces were characterized by water contact angle, X-ray photoelectron spectroscopy (XPS), and atomic force microscope (AFM). The effect of poly(MPC) chain length on fluorescence labeled albumin adsorption was studied in phosphate buffered saline buffer at pH 7 .1. The adsorption of protein on the poly(MPC)-grafted or introduced PC group surfaces was greatly reduced compared to the unmodified PE. The protein adsorption decreased with increasing chain length of grafted-poly(MPC).