Journal of Neuroendovascular Therapy
Online ISSN : 2186-2494
Print ISSN : 1882-4072
ISSN-L : 1882-4072
Volume 17, Issue 12
Displaying 1-4 of 4 articles from this issue
Original Article
  • Masahiro Nishihori, Ryo Kawase, Takashi Izumi, Hiroe Nakase, Erina Oni ...
    2023 Volume 17 Issue 12 Pages 281-285
    Published: 2023
    Released on J-STAGE: December 20, 2023
    Advance online publication: October 24, 2023
    JOURNAL OPEN ACCESS

    Objective: We verified the usefulness of patient management using a balloon-pressurized belt (Stanch Belt Plus) to prevent puncture site hematomas, which can occur at a specific rate even with hemostatic devices after endovascular neurosurgery.

    Methods: A total of 113 patients who underwent endovascular surgery with a femoral puncture from April 2019 to September 2020 were divided into two groups: 31 cases using a traditional compression belt and 82 cases using a newly introduced balloon-pressurized belt during this period. The clinical data were analyzed retrospectively. The chi-square test and Mann–Whitney U test were used to test for significant differences.

    Results: There were no significant differences in treatment procedures or frequency of hemostatic device use, but the balloon-pressurized belt group had a significantly lower incidence of hematomas (2.4% vs 12.9%, p <0.05) and a significantly lower incidence of moderate or higher lumbago (22.0% vs 41.9%, p <0.05). The incidence of epidermal detachment tended to be low; however, no significant difference was observed (3.7% vs. 12.9%, n.s.).

    Conclusion: Patient management with the newly introduced balloon-pressurized belt may decrease the occurrence of groin hematoma and lumbago among complications after endovascular neurosurgery.

    Download PDF (1129K)
Case Reports
  • Shin Hirota, Satoru Takahashi, Masataka Yoshimura, Sakyo Hirai, Takama ...
    2023 Volume 17 Issue 12 Pages 286-292
    Published: 2023
    Released on J-STAGE: December 20, 2023
    Advance online publication: September 01, 2023
    JOURNAL OPEN ACCESS

    Objective: Basilar artery occlusion (BAO) secondary to traumatic vertebral artery (VA) dissection caused by vertebral fracture is a rare cause of acute ischemic stroke, and optimal management, such as antithrombotic agents, surgical fixation, and parent artery occlusion (PAO), has been controversial. We report a case in which mechanical thrombectomy and PAO were performed for a BAO due to right VA dissection caused by a transverse foramen fracture of the axis vertebra.

    Case Presentation: A patient in her 80s suffered from a backward fall, and a neck CT revealed a fracture and dislocation of the right lateral mass of the axis and a compressed transverse foramen. The patient was instructed to admit and to remain in bed rest; however, she suddenly lost consciousness the following day. The CTA revealed right VA occlusion and BAO; therefore, the patient underwent mechanical thrombectomy and the BAO was successfully reperfused but the VA stenotic dissection remained. PAO of the right VA was performed on the fifth day after the accident to prevent BAO recurrence.

    Conclusion: Mechanical thrombectomy is an effective treatment for BAO caused by VA dissection, and PAO may contribute to the prevention of stroke recurrence.

    Download PDF (6342K)
  • Rintaro Yokoyama, Koichi Haraguchi, Kazumi Ogane, Seiichiro Imataka, Y ...
    2023 Volume 17 Issue 12 Pages 293-298
    Published: 2023
    Released on J-STAGE: December 20, 2023
    Advance online publication: September 30, 2023
    JOURNAL OPEN ACCESS

    Objective: We report a case of near-occlusion of the common carotid bifurcation caused by a giant free-floating thrombus (FFT) successfully treated with mechanical thrombectomy using a large dual-layer stent retriever.

    Case Presentation: A 51-year-old man presented to our hospital with dysarthria, right hemiparalysis, and paresthesia. MRI revealed an acute infarction of the left cortical watershed zone, and MRA revealed decreased signals in the left common carotid bifurcation. Carotid ultrasonography demonstrated a giant FFT in the left common carotid bifurcation. Angiography revealed a giant thrombus extending from the left common carotid artery (CCA) to the internal carotid artery (ICA) and the external carotid artery. As direct aspiration from both a balloon-guided catheter (BGC) and an aspiration catheter (AC) was ineffective, we deployed a large dual-layer stent retriever from the ICA to the CCA with an AC-connected aspiration pump and retrieved it under manual aspiration through the BGC. The giant thrombus was successfully removed, and complete recanalization was achieved without distal embolisms.

    Conclusion: Although there is no established treatment for giant thrombi in the carotid artery, mechanical thrombectomy using a large dual-layer stent retriever may be an effective treatment option.

    Download PDF (2928K)
  • Taro Yanagawa, Aoto Shibata, Shinya Tabata, Shunsuke Ikeda, Toshiki Ik ...
    2023 Volume 17 Issue 12 Pages 299-303
    Published: 2023
    Released on J-STAGE: December 20, 2023
    Advance online publication: October 24, 2023
    JOURNAL OPEN ACCESS
    Supplementary material

    Objective: The trans-cell technique in stent-assisted coil embolization is a common treatment method for intracranial aneurysm. However, despite the frequency of its use, reports discussing its complications and their management are few. We describe a case of stent and microguidewire entanglement, which could not be removed, during treatment using the trans-cell technique. We discuss the mechanism of the entanglement and its management.

    Case Presentation: A woman in her 40s was found to have an unruptured cerebral aneurysm with a maximum diameter of 5.9 mm located in the paraclinodal anterior process of the left internal carotid artery during a close examination of a headache. The aneurysm had an irregular shape and wide neck. Stent-assisted coil embolization was planned. Initially, the coil was embolized using a jailing technique, but the microcatheter was pushed out of the aneurysm during embolization. Thus, we attempted to switch to a trans-cell technique. However, during the process, the stent and microguidewire became entangled and could not be removed. Finally, when the stent slipped off, the entanglement was resolved and the microguidewire was retrieved. Fortunately, the patient was discharged home without postoperative complications.

    Conclusion: Once a stent and a microguidewire become entangled, safely releasing them is difficult. Thus, it is important to avoid this scenario from occurring.