Advanced Experimental Mechanics
Online ISSN : 2424-175X
Print ISSN : 2189-4752
ISSN-L : 2189-4752
Technical Note
Design of a Perforated Plate for Flow Homogenisation of Air Flowing into a Honeycomb from a Pipe Connected to the Header Section Inlet
Hiroki UCHIYAMAAtsushi OKIMOTOHideyuki UEDAYosuke MATSUKUMA
著者情報
ジャーナル フリー

2023 年 8 巻 p. 107-113

詳細
抄録

To achieve a uniform flow in a honeycomb filler, a new type of perforated plate was developed for installation inside the header located upstream of the honeycomb. The homogenisation effect was evaluated based on the pressure loss and standard deviation of the velocity. Compared to the unmodified perforated plate parameters, the maximum flow velocity near the centre of the improved perforated plate reduced to values ranging between approximately 1/17 and 1/10, and the standard deviation decreased to values ranging between approximately 1/38 and 1/9 in each honeycomb.

著者関連情報
© 2023 The Japanese Society of Experimental Mechanics
前の記事
feedback
Top