STUDY ON LCA OF LCCM ORIENTED HOUSES
The analysis method for feasibility of CO2 reduction goal with taking into account the uncertainty and the accuracy of the data
Tsuyoshi SEIKEManabu KANEMATSUKensuke KOBAYASHITakayuki ISOBEAkira NATORI
Author information
JOURNAL FREE ACCESS

2015 Volume 80 Issue 707 Pages 55-65

Details
Abstract
In this study, we provided a confidence interval for LCCO2, taking account of a difference between the amount of building materials which are estimated, ordered and used, a difference in repair of levels and period and an error of LCA data. In this estimation, 95% confidential interval of the LCCO2 is from 283kg-CO2/m2 to 3,126kg-CO2/m2. Secondly, we verified feasibility of LCCM by the CO2 balance among a reduction from 8kW-PV, an energy consumption and the confidence interval. Lastly, we clarified an interrelation between a probability of feasibility of LCCM and a reduction of CO2 of energy generating facilities.
Content from these authors
© 2015 Architectural Institute of Japan
Previous article Next article