A STUDY ON ESTIMATING METHOD OF FIXTURE DISCHARGE CHARACTERISTICS AND CARRYING PERFORMANCE OF WATER SAVING TOILETS IN HORIZONTAL DRAINAGE PIPE WITH DIFFERENT PIPING DIAMETER
Kazuya AKIYAMAMasayuki OTSUKAYusuke KUBOTAHiroshi SHIGEFUJI
Author information
JOURNAL FREE ACCESS

2024 Volume 89 Issue 822 Pages 485-493

Details
Abstract

The purpose of this study is to propose a calculation method for estimating the carrying performance of water-saving toilets installed in commercial buildings, in order to contribute to the design of drainage pipes taking into account the carrying performance. The carrying performance when a large-diameter pipe is installed in water-saving toilets has been determined by actual measurements. However, actual measurements have limitations in adapting to various pipe configurations. Therefore, in this paper, we estimate the carrying performance of straight pipes by calculating the effects of variations in flushing water volume, pipe diameter, and gradient, and evaluate their effectiveness.

Content from these authors