2025 Volume 90 Issue 838 Pages 569-577
In Japan, there are no standards that define methods for evaluating combined vibration. The aim of this study is to establish an evaluation method for tri-axis traffic vibration. Sensory test using a shaking table which can vibrate simultaneous tri-axis was conducted, and relationship between human sense and vibration was examined. As a result, a performance value C(1/√2:1:1)VLT(630ms,60dB) that relative to human’s vibratory senses were established: C(1/√2:1:1)VLT(630ms,60dB) is calculated by the maximum value of the level value combined from accelerations in three directions and the duration of the level over 60dB.
Code of Ethics
Ethical standards of the publisher (‘Ethical Standards Concerning the Peer Review for the Presentation of Architectural Transactions and Works’)