Journal of Structural Engineering B
Online ISSN : 2436-6285
Print ISSN : 0910-8033
THE EFFECT OF STIFFNESS AND STRENGTH OF COLUMN BASES IN FIRST STORY ON DAMAGE DISTRIBUTION OF WEAK-BEAM TYPE RIGID STEEL FRAMES
Yoshinobu YANAGITAYuichiro ISHINABE
Author information
JOURNAL FREE ACCESS

2023 Volume 69B Pages 352-360

Details
Abstract

Exposed-type column bases are classified by two yield types, i.e., anchor-bolt type, and base-plate type. Restoring force characteristics are slip-type and maximum point orientation type respectively. The characteristics of damage distribution in steel frames with exposed-type column bases have been clarified by many past studies. However, the literature concerning quantitative evaluation and prediction formulas is limited. The prediction formulas are needed to design such structures avoiding damage concentration as much as possible. In this paper, the damage to column bases, the upper beam of the first story, and inside the first story in steel frames with column bases that have elastic perfectly plastic restoring force characteristics are evaluated quantitatively based on the comparison with "Basic Frame". After that, the proposed prediction formula is contrasted with the time-history response analyses.

Content from these authors
© 2023 Architectural Institute of Japan
Previous article Next article
feedback
Top