Journal of Structural and Construction Engineering (Transactions of AIJ)
Online ISSN : 1881-8153
Print ISSN : 1340-4202
ISSN-L : 1340-4202
INCREMENTAL INELASTIC STIFFNESS MATRIX OF STEEL SQUARE TUBE-TO-HIGH STRENGTH PRECAST CONCRETE COMPOSITE COLUMN
Kazuo INOUEMotohide TADAKenji UEMURAHiroki MUKAI
Author information
JOURNAL FREE ACCESS

1995 Volume 60 Issue 470 Pages 133-142

Details
Abstract
The incremental inelastic stiffness matrix of the composite column is derived. In the column, high-strength four precast-concrete panels are fixed to the steel square tube with high strength headed studs. Strain softening type stress-strain relation of precast concrete panel is assumed from the test results of short column whose length is equal to the failure length decided by Mohr-Coulomb criterion. Hysteretic rule concerning shear force-to-slip relation of headed stud is also proposed based on the test results. Analytical results agree well with the hysteretic behavior of composite columns subjected to constant axial force and anti-symmetrical repeated moment.
Content from these authors
© 1995 Architectural Institute of Japan
Previous article Next article
feedback
Top