1996 Volume 61 Issue 486 Pages 63-73
A multi-story shear wall has often discrete joints without cotter reinforcements at the vertical joints between the wall panels and the surrounding cast-in-place columns. The sliding displacement in joints which display a resistance mechanism different from that of cast-in-place shear wall is expected to occur. In order to investigate the effect of resistant of joints on earthquake resistant performance, a shear failure type experiment was performed on seven multi-story precast concrete walls having a variety of cotter and joint reinforcement ratio at joints. Based on the results of this experiment, the resistance mechanism of a precast concrete multi-story shear wall and a design formula of the slip strength of horizontal joints are proposed.
Code of Ethics
Ethical standards of the publisher (‘Ethical Standards Concerning the Peer Review for the Presentation of Architectural Transactions and Works’)