Journal of Structural and Construction Engineering (Transactions of AIJ)
Online ISSN : 1881-8153
Print ISSN : 1340-4202
ISSN-L : 1340-4202
STRENGTH AND DUCTILITY OF UNEMBEDDED TYPE OF STEEL REINFORCED CONCRETE COLUMN BASE UNDER TENSILE FORCE
Ryoichi SHOHARAYoshikazu SAWAMOTOKazumasa IMAIHaruo NAKAZAWAHiroyuki NARIHARAToshiyuki FUKUMOTO
Author information
JOURNAL FREE ACCESS

2003 Volume 68 Issue 569 Pages 111-118

Details
Abstract
The unembeded type of the column bases of Steel Reinforced Concrete buildings were severely damaged by Hyougoken Nanbu Earthquake in 1995. The anchor bolts and main reinforcing bars were often broken. This is mainly due to the lack of consideration of the tensile force caused by the overturning moment during earthquakes. In this report the strength and ductility of the unembeded type of column bases are examined. The strength of a column base can be evaluated by the sum of the strength of the components unless the bond between the concrete and reinforcing bars is deteriorated. The large amount of tensile force deteriorates the ductility of the column base. We propose the formula to predict the ductility of the column base which relates the parameter "effective tensile force ratio" considering the bond strength as well as tensile strength.
Content from these authors
© 2003 Architectural Institute of Japan
Previous article Next article
feedback
Top