FIRE RESISTANCE OF REPAIRED COMPONENTS BY POLYMER-MODIFIED CEMENT MORTAR
Part 1 Damage and temperature distribution of repair section under fire test
Hitoshi HAMASAKITakeshi MOTEGITakafumi NOGUCHIDedong WANGHyungjun KIM
Author information
JOURNAL FREE ACCESS

2010 Volume 75 Issue 652 Pages 1065-1071

Details
Abstract
This paper deals with the fire resistance of repaired components by polymer-modified cement mortar. The experiment examine fire test for two hours, confirmed the damage conditions and the temperature distribution of repair sections, and adhesive strength.
As the result, the monolithic property of repair section depends on its size and thickness, the case of large and thin is relatively danger. The temperature distribution in the repair section is relatively low compared with an ordinary concrete and mortar, so harmful influence to the structural safety in fire is low from the viewpoint of the temperature of the reinforcing bar.