Journal of Structural and Construction Engineering (Transactions of AIJ)
Online ISSN : 1881-8153
Print ISSN : 1340-4202
ISSN-L : 1340-4202
EXPERIMENTAL STUDY ON IMPROVED PRECAST UNBONDED POST-TENSIONED BEAM-COLUMN JOINT SYSTEM
Thinh Tien DOKoichi KUSUNOKIAkira TASAI
Author information
JOURNAL FREE ACCESS

2011 Volume 76 Issue 659 Pages 149-156

Details
Abstract
The aim of this study is to investigate the seismic behavior of improved unbonded post-tensioned precast concrete beam-column connections with and without shear bracket. Three specimens of precast unbonded post-tensioned exterior beam-column connection were designed and tested. The test results of the specimen without shear bracket showed excessive beam slip and large residual deformation. The specimens with shear bracket expressed very satisfied performance with small residual deformation, almost no slip, fully developed strength, minor damage to the beam and column elements, and easy to disassemble. It is concluded that satisfied seismic performance can be expected from well-designed connection with shear bracket.
Content from these authors
© 2011 Architectural Institute of Japan
Previous article Next article
feedback
Top