Journal of Structural and Construction Engineering (Transactions of AIJ)
Online ISSN : 1881-8153
Print ISSN : 1340-4202
ISSN-L : 1340-4202
OVERALL TEST OUTLINE AND RESPONSE OF BUILDING WITHOUT DAMPERS
3D shake table tests on full scale 5-story steel building with dampers Part 1
Kazuhiko KASAITsuyoshi HIKINOHiroshi ITOYoji OOKIShojiro MOTOYUIFumito KATOYuki BABA
Author information
JOURNAL FREE ACCESS

2011 Volume 76 Issue 663 Pages 997-1006

Details
Abstract
Realistic three-dimensional shake table tests using E-Defense were conducted for full-scale 5-story building specimens with/without dampers to evaluate seismic performance, under ground motions of a variety of scales ranging from minor to catastrophic levels. The building was tested repeatedly, inserting and replacing each of 4 damper types, i.e., steel, viscous, oil, and viscoelastic dampers. This paper focuses on the tests conducted without dampers at the end of the whole test series, and discusses responses and properties of the steel frame portion of the specimen.
Content from these authors
© 2011 Architectural Institute of Japan
Previous article Next article
feedback