Journal of Structural and Construction Engineering (Transactions of AIJ)
Online ISSN : 1881-8153
Print ISSN : 1340-4202
ISSN-L : 1340-4202
SEISMIC PERFORMANCE OF ROOF STRUCTURE IN STEEL GYMNASIA WITH ENERGY DISSIPATION DEVICES
Toru TAKEUCHIMasato YUZAWATomohiko KUMAGAIToshiyuki OGAWA
Author information
JOURNAL FREE ACCESS

2011 Volume 76 Issue 669 Pages 1989-1995

Details
Abstract
A number of school gymnasia in Japan exhibited or lead one to foresee insufficient seismic performance, and seismic retrofits on them are still underway throughout the country. However, current assessment practices often require the replacement or addition of roof braces, which are very time and cost consuming. Energy dissipating retrofits are better suited than common strength-based retrofits to help reduce excited vibration of the roof and burden of the roof braces and ceilings, however, optimum design and evaluation methods remain unclear. This paper investigates retrofit design using elasto-plastic or viscous dampers, discussing its effects on response reduction for roof braces and practical response estimation methods, followed by proposing the retrofit method which achieves required seismic performances without replacing the roof braces.
Content from these authors
© 2011 Architectural Institute of Japan
Previous article Next article
feedback