Journal of Structural and Construction Engineering (Transactions of AIJ)
Online ISSN : 1881-8153
Print ISSN : 1340-4202
ISSN-L : 1340-4202
ESTIMATION METHOD OF HORIZONTAL CAPACITY OF JOINT FRACTURE FOR RETROFITTED FRAME USING DISK SHEAR-KEY
Study on shear-key consisted of steel disk and anchor bolt for seismic retrofitting
Yuya TAKASETakahide ABEHidehiko ITADANITakashi SATOHAtsuyoshi ONAKAMasaharu KUBOTATakaaki IKEDA
Author information
JOURNAL FREE ACCESS

2014 Volume 79 Issue 698 Pages 507-515

Details
Abstract
We developed the new joint element called “disk shear-key” for seismic retrofitting. This joint element is consisted of steel disk and anchor bolt. We had tested to clear the basic structural performance by direct shear test. Retrofitting members are connected to existing frame through indirect-joints generally. In this paper, the joint loading test and the frame loading test are conducted to investigate structural performance of disk shear-key put in indirect-joints. As a result, it is found that the horizontal load-capacity of frame is estimated by adding shear strength of column, punching shear strength and shear strength of disk shear-key constructed by the joint loading test results.
Content from these authors
© 2014 Architectural Institute of Japan
Previous article Next article
feedback
Top