Journal of Structural and Construction Engineering (Transactions of AIJ)
Online ISSN : 1881-8153
Print ISSN : 1340-4202
ISSN-L : 1340-4202
BUCKLING STRENGTH OF SLENDER RC COLUMNS SUBJECTED TO CENTRIC AXIAL LOAD IN FIRE
Study on fire resistance of slender RC columns Part 1
Masaki KATOShintaro MICHIKOSHIShigeaki BABAKazumasa IMAISatoshi WATANABE
Author information
JOURNAL FREE ACCESS

2015 Volume 80 Issue 708 Pages 345-355

Details
Abstract
The fire resistance of high-strength (120N/mm2) slender RC columns is evaluated by conducting experiments and also by finite-element analysis. Experimental parameters are the ratio of column height to cross-section diameter and the axial loading of the specimens, while the results obtained are fire resistance time and failure mode. A proposed finite-element method of evaluating critical buckling strength based on tangent-modulus theory is then applied to the columns. In a parametric study using this method, the results indicate that the amount of transient strain and main reinforcement strength have little influence on buckling strength.
Content from these authors
© 2015 Architectural Institute of Japan
Previous article Next article