Journal of Structural and Construction Engineering (Transactions of AIJ)
Online ISSN : 1881-8153
Print ISSN : 1340-4202
ISSN-L : 1340-4202
VERIFICATION OF STRENGTH REDUCTION FACTOR RELATED TO OPENING HEIGHT FOR RC SHEAR WALLS
Yasushi SANADAToshikatsu ICHINOSESusumu TAKAHASHIMomoko IIZUKA
Author information
JOURNAL FREE ACCESS

2015 Volume 80 Issue 709 Pages 481-490

Details
Abstract
A new reduction factor related to opening height has been adopted for shear wall design in the AIJ standard since 2010. This factor has not been verified experimentally, while it was presented theoretically. Moreover, the other reduction factor legally regulates shear wall design according to the MLIT (Japanese government) regulation. This paper reports laboratory tests to verify agreements between these reduction factors and experimental results. Three 1/6 scale shear wall specimens were tested with different opening configurations. Consequently, it was concluded that the AIJ reduction factor underestimated the strength drops due to openings but the MLIT reduction factor overestimated.
Content from these authors
© 2015 Architectural Institute of Japan
Previous article Next article
feedback
Top