Journal of Structural and Construction Engineering (Transactions of AIJ)
Online ISSN : 1881-8153
Print ISSN : 1340-4202
ISSN-L : 1340-4202
EQUIVALENT STATIC SEISMIC LOAD FOR MIDDLE TO LARGE SPAN LATTICED DOMES CONSIDERING ROOF ANTISYMMETRIC MODE AMPLIFIED BY SUBSTRUCTURE SECOND MODE
Yuki TERAZAWADeepshikha NAIRKeita ICHIHASHIToru TAKEUCHI
Author information
JOURNAL FREE ACCESS

2022 Volume 87 Issue 792 Pages 194-204

Details
Abstract

A series of modal response spectrum analyses were performed on 60m to 150m spanned lattice domes with the half subtended angle ranging from 20 deg. to 30 deg. to investigate the effect of the dynamic characteristics of the substructure’s higher mode. It was found that the current equivalent static seismic loads underestimate the roof response when supported by multi-story substructure with the 1st natural period in the range of 0.5s to 1.2s. Therefore, a modified equivalent static seismic load considering the antisymmetric roof mode’s amplification by the substructure’s second mode was proposed and validated.

Content from these authors
© 2022, Architectural Institute of Japan
Previous article Next article
feedback
Top