2023 Volume 88 Issue 811 Pages 1318-1326
Segregation resistance and passing ability of high fluidity concrete with slump flow of 45 cm were investigated. The following findings were obtained as the results. (1) The Filling ability with passing between rebars is estimated by PJ value of the J-ring test. (2) The segregation resistance while passing between rebars is not matter too much. (3) The degree of settling of coarse aggregate is estimated by the ratio of coarse aggregate content in chamber B of the box-type filling test with vibration. Moreover, significant that due to excess compaction is estimated by visual examination of the slump flow.
Code of Ethics
Ethical standards of the publisher (‘Ethical Standards Concerning the Peer Review for the Presentation of Architectural Transactions and Works’)