2026 Volume 91 Issue 843 Pages 604-614
Seismically isolated buildings are required to secure a safety margin against extreme ground motion. A possible countermeasure is to install a fail-safe mechanism in the seismic isolation layer. In this study, the fail-safe mechanism using bent steel plates is proposed, and the mechanical properties of the fail-safe mechanism are investigated by shear loading test and finite element analysis. Furthermore, the hysteresis model of the fail-safe mechanism is proposed, and the influence of hysteresis characteristics of the fail-safe mechanism on the seismic response of seismically isolated buildings is investigated by time history response analysis.
Code of Ethics
Ethical standards of the publisher (‘Ethical Standards Concerning the Peer Review for the Presentation of Architectural Transactions and Works’)