Abstract
Column bases embedded in base concrete have sufficient rigidities and strength when the embedded portion of the column is long enough to transmit the bending moment developed at the base of the column. A series of experiments was carried out on bases of steel columns with H-section shape bent about the strong axis of the cross section and the results were summarrized into an empirical formula which may predict the collapse mode and the ultimate bending moment capacity of the column base.