AIJ Journal of Technology and Design
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
PROPOSAL OF STRUCTURAL SYSTEM OF DOUBLE WOOD SIDING WALL AND HORIZONTAL LOADING TEST(Architectural Planning and Design)
Mahito NAKAZONONaotoshi FUJIShinji IWATAKazuya BONKOBARAEiichi INAIHitomi MURAKAMI
Author information
JOURNAL FREE ACCESS

2006 Volume 12 Issue 23 Pages 315-320

Details
Abstract

The authors have developed wooden shear wall constituted by double wood siding board made by foothold boards. This new system can secure the insulation and air humidity control performance. It has been proven that the wall has endurance for practical use by horizontal loading test. As a result, the initial stiffness of test specimen with dowel has indicated high value, and wall magnification also has indicated twice or more value conpared with the notification, so the practicality of this system has been confirmed.

Content from these authors
© 2006 Architectural Institute of Japan
Previous article Next article
feedback
Top