AIJ Journal of Technology and Design
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
EXPERIMENTAL STUDY ON BOND STRENGTH BETWEEN CERAMIC TILE AND PRECAST CONCRETE COLUMN USING 150MPa CONCRETE(Materials and Construction)
Hiroshi KUBOTAHiroshi JINNAIShusuke KUROIWASatoshi WATANABERieko TERAUCHIMitsuo SHIMONOAtsushi HATTORITomohiro TERASHIMA
Author information
JOURNAL FREE ACCESS

2006 Volume 12 Issue 24 Pages 15-20

Details
Abstract

Precast columns using 150MPa concrete were produced, and bond strength of the ceramic tile was investigated. As a result, the following conclusions were obtained. (1) Bond strength of tile in 150 MPa concrete column was higher than that of 60 MPa concrete column. (2) Bond strength of most tiles was high enough compared with a regulated value. (3) It was useful for the improvement of bond strength to paint the acrylic silicon resin on the backside of the tile. (4) The direction of the back foot did not influence bond strength of the tile.

Content from these authors
© 2006 Architectural Institute of Japan
Previous article Next article
feedback
Top