Abstract
The author thanks Masatoshi Yamazaki, for his discussion, and the answers are as follows;
Method of testing on the adiabatic temperature rise is similar to the type A of referred paper 1). The close adiabatic temperature rise simulation is not confirmed.
Cumulative strain is measured value accurately. It was observed shrinking in restraint by the equipment self-rigidity.