AIJ Journal of Technology and Design
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
Structures
INFLUENCES OF TENON SIZE ON PULL OUT AND BENDING STRENGTH OF MORTISE-TENON JOINT WITH PIN
Yasutaka IRIEShinya OIFUJI
Author information
JOURNAL FREE ACCESS

2009 Volume 15 Issue 29 Pages 127-131

Details
Abstract
In order to investigate the most suitable tenon size of the mortise-tenon joint with pin, we carried out the static horizontal loading tests. The main results obtained from these tests and analytical investigations are as follows.
Mortisize-tenon joint thickness of which is 45mm improves the stiffness and strength by about 50% compared with that of using tenon of 30mm thickness. The analytical model shown in Fig. 19 expresses the stiffness and bearing force after yielding point.
Content from these authors
© 2009 Architectural Institute of Japan
Previous article Next article
feedback
Top