Abstract
This paper presents the remaining strength and plastic deformation capacity of the corroded steel member. They are confirmed by an experiment and analysis, about following two cases. 1) Tensile strength is predicted from calculated strength using the minimum of the section average thickness. 2) Shear strength of corroded bolted connection is predicted from calculated strength using average thickness on an expected breaking line.